Dryer |
||
Display |
Description |
Cause/Corrective Action |
Alrn, ALrn or ALArn |
Service the service door or coin vault switches. |
|
door |
Door Open Indicator |
Door is not closed during an active cycle. If door is closed, check for improper wiring or inoperative door switches. |
E rr or Err |
Coin Error |
Invalid coin pulse or inoperative coin sensor. Check coin drop area and remove obstructions. If error persists, tampering may have occurred. Evaluate security procedures. |
E:00 |
General Error |
Re-aim external device and try again. |
E:01 |
Proximity Error |
External device is improperly aimed at infrared communicator (angle or distance). Re-aim external device and try again. |
E:02 |
IR Communication Disconnection |
External device removed before communication complete. Re-aim external device and try again. |
E:05 |
Invalid Value Communication |
Invalid code downloaded from external device to Electronic Control. Before downloading, ensure data is for current machine type. |
E:07 |
Inoperative Control |
Replace control. |
E:08 |
Inoperative Control |
Replace control. |
E:09 |
Proximity Error |
External device is improperly aimed at infrared communicator (angle or distance). Re-aim external device and try again. |
E:0A |
Proximity Error |
External device is improperly aimed at infrared communicator (angle or distance). Re-aim external device and try again. |
E:0B |
IR Communication Disconnection |
External device removed before communication complete. Re-aim external device and try again. |
E:0C |
IR Communication Disconnection |
External device removed before communication complete. Re-aim external device and try again. |
E:0F |
IR Communicator Programmed Off |
Reprogram infrared communicator on. Manually enable IR on control/Re-aim external device and try again. |
E:OP |
Open Temperature Sensor Error |
Open temperature sensor circuit wiring. Change sensor. |
E:SH |
Shorted Temperature Sensor Error |
Short in temperature sensor circuit wiring. Change sensor. |
EC:00 |
General Communication Error |
Communication failure. Try card again. |
EC:02 or EC02 |
Timeout Error |
Communication failure. Try card again. |
EC:03 or EC03 |
Invalid Command Code |
Communication successful, but the command was not valid for this machine type, or the control could not perform the command in its current mode of operation. Before downloading, ensure data is for current machine type and control is in correct mode. |
EC:05 or EC05 |
Invalid or Out-of-Range Data |
Incorrect machine type or the value in at least one of the programming options is invalid or out of range. Before downloading, ensure data is for current machine type and recheck the programming option's value and try again. |
EC:06 |
Invalid Data Code |
Incorrect machine type. Before downloading, ensure data is for current machine type. |
EC:09 |
Corrupted Data Error |
Communication error. Try card again. |
Dryer |
||
Display |
Description |
Cause/Corrective Action |
EC:0A |
Invalid Machine Type |
Incorrect machine type. Before downloading, ensure data is for current machine type. |
EC:19 or EC19 |
No Card Reader Communication |
Communication failure. Check card reader, control and harness. Power down, power up and try again. If error persists, replace control or card reader. |
EC:20 |
Unreadable Card |
Inoperative card/ dirty contact. Clean chip on card or card reader contacts. Try card again. If error persists, card may be inoperative. |
EC:21 |
Security ID Mismatch |
Wrong card. Use card with correct security code. |
EC:22 |
Site Code Mismatch |
Wrong card. Use card with correct site code. |
EC:23 |
Card Maximum Value Exceeded |
Value on card over max. Use a card which does not exceed maximum value. |
EC:24 |
Insufficient Memory on Card |
Card memory is full. Download card contents to PC and clear card for re-use. |
EC:25 |
Card Reader Malfunction |
Inoperative Card Reader. Card Reader may need to be replaced. |
EC:26 |
Card Write Error |
Try card again. If error persists, card may be inoperative. |
EC:27 |
Diagnostic Test Card Write Failure |
Inoperative Card Reader. Card Reader may need to be replaced. |
EC:28 |
Diagnostic Test Card Read Failure |
Inoperative Card Reader. Card Reader may need to be replaced. |
EC:29 |
Diagnostic Test Memory Test Failure |
Inoperative Card Reader. Card Reader may need to be replaced. |
EC:2A |
Diagnostic Test Card Interface Failure |
Inoperative Card Reader. Card Reader may need to be replaced. |
EC:2b |
Diagnostic Test Flash Checksum Failure |
Inoperative Card Reader. Card Reader may need to be replaced. |
EC:2C |
Biberon or Non-biberon Device Failure |
Faulty card reader. Replace card reader. |
EC:2d |
Firmware Update Failed, S/W (Software) Intact |
Firmware load failed. Replace card reader. |
EC:2E |
Firmware Update Failed, S/W Not Intact |
Faulty firmware in reader. Replace card reader |
EC:2F |
Firmware Updated, S/W Not Intact |
Faulty firmware in reader. Replace card reader. |
Dryer |
||
Display |
Description |
Cause/Corrective Action |
EC:30 |
Timeout Error |
Card Reader may need to be replaced |
EC:31 |
Hotlisted Card Inserted Into Reader |
Card hotlisted. Control will destroy card. |
EC:50 |
Loyalty Purse Read Error |
Try card again. If error persists, card may be inoperative. |
EC:56 |
Loyalty Purse Write Error |
Try card again. If error persists, card may be inoperative. |
EC11 |
No Card Reader Initialization |
Communication is valid, but there is no card reader initialization. Power down, power up and try again. |
EC18 |
No Communication |
Card reader initialized, communication lost. Power down, power up and try again. If error persists, replace control or card reader. |
EC36 |
Audit Card Removed Prematurely |
Re-insert audit card and wait until machine prompts for card removal. |
EI:00 |
General Communications Errors |
Communication failure. Re-aim external device and try again. |
EI:01 or EI01 |
Transmission Failure |
Communication failure. Re-aim external device and try again. |
EI:02 or EI02 |
Device Timeout/Timeout Error |
Communication failure. Re-aim external device and try again. |
EI:03 or EI03 |
Invalid Command Code |
Communication successful, but the command was not valid for this machine type, or the control could not perform the command in its current mode of operation. Ensure data is for current machine type and control is in correct mode. |
EI:04 or EI04 |
Expecting Upload Request or Command Packet Time Out |
Communication failure. Re-aim external device and try again. |
EI:05 or EI05 |
Invalid or Out-of-Range Data |
Incorrect machine type or the value in at least one of the programming options is invalid or out of range. Before downloading, ensure data is for current machine type, values entered are within the minimum and maximum limits and recheck the programming option's value and try again. |
EI:06 |
Invalid Data Code |
Incorrect machine type. Before downloading, ensure data is for current machine type. |
EI:07 |
Error Writing to RTC |
Control failure. Control may need to be replaced. |
EI:08 |
Error Writing to EPROM |
Control failure. Control may need to be replaced. |
Dryer |
||
Display |
Description |
Cause/Corrective Action |
EI:09 or EI09 |
CRC-16 Error |
Communication failure. Re-aim external device and try again. |
EI:0A |
Invalid Machine Type |
Incorrect machine type. Before downloading, ensure data is for current machine type. |
EI:0F or EI0F |
Invalid Wakeup or IR Disabled |
Communication failure or IR is disabled. Manually enable IR on control/Re-aim external device and try again. |
EI0A |
Framing Error |
Communication error. Re-aim external device and try again. |
EI0C |
Time-out Exceeded |
Communication error. Re-aim external device and try again. |
EI0E |
Encryption Error |
Incorrect machine type. Before downloading, ensure data is for current machine type and check security code and retry. |
EoP or E oP |
Remove any lint build-up around thermistor. If problem persists, replace control or thermistor. |
|
ESH or E SH |
Shorted Thermistor Error |
Remove any lint build-up around thermistor. If problem persists, replace control or thermistor. |
E id |
Board ID |
Incorrect replacement control. Replace user control or output board with correct part. |
E dS |
Brownout/Voltage Configuration |
Unexpected supply voltage. Check the harness connections between the user control and the output board. If the user control was replaced, set dipswitch #1 to the same setting as the previous control. If reworking the machine to use a different supply voltage, the dip switch #1 setting may need to be changed. If the dip switch #1 setting is changed, power down, power up and try again. |
E nr |
Output Board Not Ready |
Hardware failure. Replace output board. |
E bS |
Output Board Communication |
Hardware failure. Replace output board. |
EnXX |
Machine ID |
Communication failure. Power down, power up and try again. If error persists, check connection between user control and Machine ID chip, or try replacing the user control or the Machine ID chip. |
Dryer |
||
Display |
Description |
Cause/Corrective Action |
E Co |
Output Board Communication |
Communication failure. Power down, power up and try again. If error persists, check connection between user control and output board, or try replacing the user control or the output board. |
E 59 |
Door Input Acquisition |
Hardware failure. Replace output board. |
E 60 |
Centrifugal Switch Input Acquisition |
Hardware failure. Replace output board. |
E 61 |
High Limit Thermostat Input Acquisition |
Hardware failure. Replace output board. |
E ro |
Locked Rotor |
The motor is not sensed as rotating when it should be. Check that nothing is obstructing motor rotation, check connection between user control and output board, or try replacing the user control or the output board. |
E nS |
Motor Output Shorted |
Hardware failure. Replace output board. |
IN USE LED blinks three times + 1.5 second pause |
Shorted Thermistor Error |
If the control sense a temperature greater than 210±4°F during an active cycle it will set a Shorted Thermistor error. The control will flash the IN USE LED three times separated by a one and a half second pause. This sequence is repeated as long as the Shorted thermistor error is sensed. |
IN USE LED blinks twice + 1.5 second pause |
Open Thermistor Error |
If the control sense a temperature less than 0°F when the heat has been on for at least three minutes it will set an open thermistor error. The control will flash the IN USE LED twice separated by a one and a half second pause. This sequence is repeated as long as the Open Thermistor error is sensed. |
OFF or oFF |
Break-in Alarm Shutdown Error |
Service the service door or coin vault switches. |
OP |
Open Thermistor Error |
Physical open in the thermistor circuit. Replace thermistor. Possible causes are: 1) thermistor, 2) wiring between control and thermistor or 3) control. |
Right most DP (decimal point) Lit |
Network Communication Error |
Communication failure. Wait for 1.5 minutes for error to clear. If it doesn’t, power-down and power-up the machine. If error persists, control or Network Board may need to be replaced. |
SH |
Shorted Thermistor Error |
Dead short int he thermistor circuit. Replace thermistor. Possible causes are: 1) shorted thermistor, 2) a short in the wiring between control and thermistor or 3) control. |