Tumble Dryer |
||
Display |
Description |
Cause/Corrective Action |
AF (flashing) |
Airflow switch opened/closed 5 or more times during cycle. Check airflow switch. Replace if inoperative. |
|
AF (solid) |
Airflow Switch Closed When Resuming Cycle |
Allow up to 20 seconds for this condition to clear. Check if airflow switch opens at end of cycle. Replace if inoperative. |
AF-1 |
Airflow Switch Closed When Cycle Started |
Switch fails to open at end of cycle. Check airflow switch. Replace if inoperative. |
AF-2 |
Airflow switch failed to close after cycle started. Check airflow switch. Replace if inoperative. |
|
Airflow Switch Bounces During A Running Cycle |
Airflow Switch Bounces During A Running Cycle |
If airflow switch is open for at least one second, heat will be turned off and will remain off until switch is observed closed for at least 5 seconds. If there are 5 airflow switch bounces within 5 minutes control will go to Cool Down portion of cycle, display error message and sound audio signal. When Cool Down portion of cycle ends, control will continue displaying error message until power is cycled or BACK keypad is pressed. |
Airflow Switch Does Not Close After Cycle Started |
Airflow Switch Does Not Close After Cycle Started |
If airflow switch does not close within 5 seconds of start/ re-start of a cycle, control will go to Cool Down portion of cycle, display error message and sound audio alarm. Once Cool Down portion of cycle ends, control will continue to display error message until power is cycled to machine or BACK keypad is pressed. |
Airflow Switch Sensed Closed While Not In Run Mode |
Airflow Switch Sensed Closed While Not In Run Mode |
If airflow switch is sensed closed 30 seconds after entering Idle Mode, or End of Cycle Mode, control will display error message until power is cycled or error clears. Cycle will not start and all user inputs will be ignored. If error does clear, control will go back to previous mode of operation. |
Alrn |
Break-in Alarm Error |
Service door or coin vault switches. |
Tumble Dryer |
||
Display |
Description |
Cause/Corrective Action |
Auto Ignition Retry (Gas Models Only) |
Auto Ignition Retry |
If Ignition Control Module (ICM) fails to ignite gas valve ICM will send an ICM Lockout Alarm to the control.If ICM needs to be manually reset, when control receives ICM Lockout Alarm it will display Cycle Stopped Menu with text prompting user to press START/ENTER keypad. If ICM fails to ignite gas on last attempt of auto retry, control will start Cool Down portion of cycle, display heat error message and sound audio signal. When Cool Down portion of cycle ends control will continue to display error message until power is cycled to machine or a user presses BACK keypad. |
DIP Switch/Harness Index Mismatch Error |
DIP Switch/Harness Index Mismatch Error |
On power up control reads Temperature Index Harness value and compares that with the value of switch 1, switch 2 and switch 3 on DIP switch configuration. If the result is an invalid setup control will not enter Idle mode and instead enter Error Mode. Control will ignore all user inputs and display error message. Machine must be powered down and correct temperature index harness must be installed and/or DIP switch configuration must be corrected. |
door |
Door Open Indicator |
Door is not closed during an active cycle. If door is closed, check for improper wiring or inoperative door switches. |
E Cab |
Cabinet Limit Error |
Remove any lint build-up around thermostat. If problem persists, replace control or thermostat. |
E FCOn |
Fan Motor Contactor Error |
Inspect wires to the fan motor contactors. Check signal to the output control. If problem persists, replace fan motor contactor. |
E FnCS |
Fan Motor Centrifugal Switch Error |
Clean vents on the fan motor. Inspect wires to the fan motor centrifugal switch. If problem persists, replace fan motor. |
E Heat |
Machine Did Not Reach Expected Temperature |
The ignition control has power, but a flame was not sensed after the programmed amount of retries. Be sure that gas is turned on. If problem persists, troubleshoot the ignition circuit. (Igniter, Cable, Ignition Control Module.) |
E Ht |
Machine Did Not Reach Expected Temperature |
Check heating connections, cycle power to machine. NOTE: To avoid error code "E Ht" on steam-heated tumblers, the Auto Ignite Retry (AIg) must be reset from the factory default of 3 to disabled (0). |
Tumble Dryer |
||
Display |
Description |
Cause/Corrective Action |
E iCn |
ICM lockout Alarm Active |
Check that the gas is turned on and that the ignition circuit functions. Also check that the gas valve is operational. |
E rot |
Check for broken or worn belts. Make sure machine is not over loaded and check if rotation sensor is working. If problem persists, replace rotation sensor or control. |
|
E rr |
Coin Error |
Invalid coin pulse or inoperative coin sensor. Check coin drop area and remove obstructions. If error persists, tampering may have occurred. Evaluate security procedures. |
E SL |
Stove Limit 1 Error |
Inspect tumble dryers venting/ventwork to ensure that the ventwork is adequate and that there are no blockages. Be sure to clean and inspect lint screen. Remove any lint build-up around the thermostat. If problem persists, replace thermostat. |
E SL2 |
Stove Limit 2 Error |
Inspect tumble dryers venting/ventwork to ensure that the ventwork is adequate and that there are no blockages. Be sure to clean and inspect lint screen. Remove any lint build-up around the thermostat. If problem persists, replace thermostat. |
E:OP |
Open Temperature Sensor Error |
Open temperature sensor circuit wiring. Change sensor. |
E:SH |
Shorted Temperature Sensor Error |
Short in temperature sensor circuit wiring. Change sensor. |
EAF |
Switch bounces during cycle. Once error is cleared, control will go back to previous mode of operation. |
|
EAF1 |
Airflow Switch Error |
Switch fails to open at end of cycle. Inspect lint screen and ductwork. Cycle power to machine (power down, then power up). Once error is cleared, control will go back to previous mode of operation. |
EAF2 |
Airflow Switch Error |
Switch does not close after cycle starts. Inspect lint screen and ductwork. Cycle power to machine (power down, then power up). Once error is cleared, control will go back to previous mode of operation. |
EC:00 |
General Communication Error |
Communication failure. Try card again. |
EC:02 or EC02 |
Timeout Error |
Communication failure. Try card again. |
Tumble Dryer |
||
Display |
Description |
Cause/Corrective Action |
EC:03 or EC03 |
Invalid Command Code |
Communication successful, but the command was not valid for this machine type, or the control could not perform the command in its current mode of operation. Before downloading, ensure data is for current machine type and control is in correct mode. |
EC:05 or EC05 |
Invalid or Out-of-Range Data |
Incorrect machine type or the value in at least one of the programming options is invalid or out of range. Before downloading, ensure data is for current machine type and recheck the programming option's value and try again. |
EC:06 |
Invalid Data Code |
Incorrect machine type. Before downloading, ensure data is for current machine type. |
EC:09 |
Corrupted Data Error |
Communication error. Try card again. |
EC:0A |
Invalid Machine Type |
Incorrect machine type. Before downloading, ensure data is for current machine type. |
EC:19 or EC19 |
No Card Reader Communication |
Communication failure. Check card reader, control and harness. Power down, power up and try again. If error persists, replace control or card reader. |
EC:20 |
Unreadable Card |
Inoperative card/ dirty contact. Clean chip on card or card reader contacts. Try card again. If error persists, card may be inoperative. |
EC:21 |
Security ID Mismatch |
Wrong card. Use card with correct security code. |
EC:22 |
Site Code Mismatch |
Wrong card. Use card with correct site code. |
EC:23 |
Card Maximum Value Exceeded |
Value on card over max. Use a card which does not exceed maximum value. |
EC:24 |
Insufficient Memory on Card |
Card memory is full. Download card contents to PC and clear card for re-use. |
EC:25 |
Card Reader Malfunction |
Inoperative Card Reader. Card Reader may need to be replaced. |
EC:26 |
Card Write Error |
Try card again. If error persists, card may be inoperative. |
EC:27 |
Diagnostic Test Card Write Failure |
Inoperative Card Reader. Card Reader may need to be replaced. |
EC:28 |
Diagnostic Test Card Read Failure |
Inoperative Card Reader. Card Reader may need to be replaced. |
EC:29 |
Diagnostic Test Memory Test Failure |
Inoperative Card Reader. Card Reader may need to be replaced. |
EC:2A |
Diagnostic Test Card Interface Failure |
Inoperative Card Reader. Card Reader may need to be replaced. |
Tumble Dryer |
||
Display |
Description |
Cause/Corrective Action |
EC:2b |
Diagnostic Test Flash Checksum Failure |
Inoperative Card Reader. Card Reader may need to be replaced. |
EC:30 |
Timeout Error |
Card Reader may need to be replaced |
EC:31 |
Hotlisted Card Inserted Into Reader |
Card hotlisted. Control will destroy card. |
EC:50 |
Loyalty Purse Read Error |
Try card again. If error persists, card may be inoperative. |
EC:56 |
Loyalty Purse Write Error |
Try card again. If error persists, card may be inoperative. |
EC11 |
No Card Reader Initialization |
Communication is valid, but there is no card reader initialization. Power down, power up and try again. |
EC18 |
No Communication |
Card reader initialized, communication lost. Power down, power up and try again. If error persists, replace control or card reader. |
EC36 |
Audit Card Removed Prematurely |
Re-insert audit card and wait until machine prompts for card removal. |
EI:00 |
General Communications Errors |
Communication failure. Re-aim external device and try again. |
EI:01 or EI01 |
Transmission Failure |
Communication failure. Re-aim external device and try again. |
EI:02 or EI02 |
Device Timeout/Timeout Error |
Communication failure. Re-aim external device and try again. |
EI:03 or EI03 |
Invalid Command Code |
Communication successful, but the command was not valid for this machine type, or the control could not perform the command in its current mode of operation. Before downloading, ensure data is for current machine type and control is in correct mode. |
EI:04 or EI04 |
Expecting Upload Request or Command Packet Time Out |
Communication failure. Re-aim external device and try again. |
EI:05 or EI05 |
Invalid or Out-of-Range Data |
Incorrect machine type or the value in at least one of the programming options is invalid or out of range. Before downloading, ensure data is for current machine type, values entered are within the minimum and maximum limits and recheck the programming option's value and try again. |
EI:06 |
Invalid Data Code |
Incorrect machine type. Before downloading, ensure data is for current machine type. |
EI:07 |
Error Writing to RTC |
Control failure. Control may need to be replaced. |
EI:08 |
Error Writing to EPROM |
Control failure. Control may need to be replaced. |
Tumble Dryer |
||
Display |
Description |
Cause/Corrective Action |
EI:09 or EI09 |
CRC-16 Error |
Communication failure. Re-aim external device and try again. |
EI:0A |
Invalid Machine Type |
Incorrect machine type. Before downloading, ensure data is for current machine type. |
EI:0F or EI0F |
Invalid Wakeup or IR Disabled |
Communication failure or IR is disabled. Manually enable IR on control/Re-aim external device and try again. |
EI0A |
Framing Error |
Communication error. Re-aim external device and try again. |
EI0C |
Time-out Exceeded |
Communication error. Re-aim external device and try again. |
EI0E |
Encryption Error |
Incorrect machine type. Before downloading, ensure data is for current machine type and check security code and retry. |
EnoiSt |
Moisture Sensor Error |
Push Back keypad to clear the error. |
EoP |
Open Termistor Error |
Remove any lint build-up around thermistor. If problem persists, replace control or thermistor. |
Err |
Coin Error |
Invalid coin pulse or inoperative coin sensor. Check coin drop area and remove obstructions. If error persists, tampering may have occurred. Evaluate security procedures. |
ESEtUP |
DIP Switch Configuration Size Mismatch Error |
Check temperature index harness and dipswitch settings. If problem persists, replace temperature index harness or control. |
ESH |
Shorted Thermistor Error |
Remove any lint build-up around thermistor. If problem persists, replace control or thermistor. |
Fan Motor Centrifugal Switch Error |
Fan Motor Centrifugal Switch Error |
If control attempts to turn on fan motor and fan motor contactor is sensed closed but Fan Motor Centrifugal Switch fails to close, control will go into Cool Down portion of cycle, display error message and turn on audio signal. Once Cool Down portion of cycle ends, control will continue displaying error message until power is cycled or BACK keypad is pressed. |
Tumble Dryer |
||
Display |
Description |
Cause/Corrective Action |
Fan Motor Contactor Error |
Fan Motor Contactor Error |
If control attempts to turn on heater relay and control does not sense Fan Motor Contactor is closed, control will go to Cool Down portion of cycle, display error message and turn on audio signal. Once Cool Down portion of cycle ends, control will continue displaying error message until power is cycled or BACK keypad is pressed. |
Moisture Sensor Error |
Moisture Sensor Error |
While in Idle Mode and on Cycle Menu, control will begin to monitor moisture sensor input after one minute without user input. If moisture sensor circuitry detects a load present signal read consistently (every second) for a ten minute period without user input, control will declare, a load sensed. |
Network Communications Error |
Network Communications Error |
Error may occur during communication with a network. When error occurs, it has no affect on an active machine cycle. |
OFF or oFF |
Break-in Alarm Shutdown Error |
Service door or coin vault switches. |
OP |
Open Thermistor Error |
Check wiring diagram between control and thermistor. Check thermistor and replace if inoperative. Check control and replace if inoperative. |
Open Thermistor Error |
Open Thermistor Error |
When control senses temperature less than 0 °F after first three minutes of active cycle, will go to Cool Down, display error message, and turn on audio signal. Error message will continue until any keypads are pressed, Cool Down cycle has ended, and temperature reading is greater than 0°F. Once all three occur, control will return to Idle Mode. |
PDA Communications Error |
PDA Communications Error |
Error may occur during communications. When error occurs, the display indicates error message on control for a few seconds. An active machine cycle is not affected |
Right most DP (decimal point) Lit |
Network Communication Error |
Communication failure. Wait for 1.5 minutes for error to clear. If it doesn’t, power-down and power-up the machine. If error persists, control or Network Board may need to be replaced. |
rot |
Rotation Sensor |
No cylinder rotation detected. |
Tumble Dryer |
||
Display |
Description |
Cause/Corrective Action |
Rotation Sensor Error |
Rotation Sensor Error |
If machine is equipped, control will constantly monitor input and calculate cylinder’s rpm. If rpm drops to zero while cylinder is supposed to be spinning, control will go to Cool Down portion of cycle. Once Cool Down portion ends, control will continue to display error message until power is cycled to machine or correct keypad is pressed. |
SH |
Shorted Thermistor Error |
Check wiring diagram between control and thermistor. Check thermistor and replace if inoperative. Check control and replace if inoperative. |
Shorted Thermistor Error |
Shorted Thermistor Error |
When control senses temperature greater than 210 + 4 °F during an active cycle, control will enter Cool Down portion of cycle, display error message, and turn on audio signal. Error message will continue until any keypads are pressed, Cool Down cycle has ended, and temperature reading is less than 210 °F. Once all three occur, control will return to Idle Mode. |
Stove and Cabinet Limit Errors |
Stove and Cabinet Limit Errors |
While heat relay is on, if stove temperature or cabinet temperature reaches high temperature for particular limit thermostat, heater will turn off automatically and control will continue cycle with no heat until limit thermostat resets. Once control reaches End of Cycle it will display appropriate error message, and sound audio signal. Control will continue displaying error message until it returns to Idle mode. On models where stove and cabinet limit thermostats need to be manually reset, thermostat(s) must be reset prior to cycling power or control will return back to Error Mode. |
UEn |
Airflow Switch |
Airflow switch is in open position or is faulty. |