Washer-Extractor (Ripon made) |
||
Display |
Description |
Cause/Corrective Action |
00 |
Programming Key Error |
Programming key in wrong place. Correct position of program key. |
01 |
General Error |
Not used. No action required. |
02 |
Program Error |
Program selected does not exist. Select another program. |
03 |
General Error |
Appears when processor is energized the first time. No action required. |
03 |
Memory Error |
Failure of RAM memory. Replace RAM memory. |
04 |
Water Level Error |
Water level not reached after 15 minutes. Check inlet water supply, water valves, drain valve and water level switch. |
06 |
Temperature Error |
Programmed temperature was not reached after 60 minutes. Check auxillary heating system, inspect drain valve and check water level switch. |
07 |
Level Switch Error |
Level switch detects water remaining in the drum at the end of the cycle. Inspect drain valve and check drain outlet. |
08 |
Temperature Sensor Error |
The temperature sensor or temperature sensor circuit is defective. Replace temperature sensor. Repair sensor wiring. |
09 |
Motor Thermal Error |
Motor thermal protector was activated. Check the following: motor, motor connections, contactors, input voltage, inverter, motor and machine bearings and print board (if applicable). |
10 |
Out of Balance Error |
Out of balance switch was activated at the start of a cycle. Check for an unbalanced load. |
11 |
Level Switch Error |
Level switch detects water in the drum at the start of a cycle. Inspect inlet water valves and inspect drain valve. |
12 |
Drain Error |
Water was not drained after three minutes. Inspect drain valve and check drain output. |
A0 |
Program Error |
Program key in wrong position when trying to access Program Mode. Correct position of program key. |
A2 |
Program Error |
Program selected does not exist. Select another program. |
A3 |
Program Error |
Program was not pre-programmed or memory has been lost. Replace E Prom. |
A4 |
Water Level Program Error |
Programmed water level was not reached after 15 minutes. Check inlet water supply, inlet water valves, drain valve and water level switch. |
Washer-Extractor (Ripon made) |
||
Display |
Description |
Cause/Corrective Action |
A5 |
Temperature Program Error |
Programmed temperature was not reached after 60 minutes. Check auxillary heating systems, inspect temperature sensor and check water safety level switch. |
A6 |
Temperature Error |
Temperature in the cylinder is unsafe at the end of the cycle. Allow laundry to cool down before removing. |
A7 |
Drain Error |
Level switch detects water remaining in the drum at the end of the cycle. Inspect drain valve and drain outlet. |
A8 |
Temperature Sensor Error |
Temperature sensor or temperature sensor circuit is defective. Replace temperature sensor. Repair sensor wiring. |
A9 |
Motor Thermal Error |
Motor thermal protector was activated. Check the following: motor, motor connections, contactors, input voltage, inverter, motor and machine bearings. |
Ab |
Drain Error |
Level switch detects water remaining in the drum at the end of the cycle. Inspect inlet water valves and drain valve. |
Ac |
Drain Error |
Water was not drained after three minutes. Inspect drain valve and drain outlet. |
Ad |
Speed Sensor Error |
The machines is not running at correct RPM or speed sensor is defective (if Ad is blinking it will take 4-5 minutes to unlock door). Check door lock circuit. Inspect door lock mechanism. |
AE |
Position Error |
Cylinder cannot find the correct position (Hygienic machines only). Press "NO" to position tub at load or unload side, press "1" to open load door and press "2" to open unload door. |
AG |
Speed Sensor Error |
The final spin was at a lower RPM (Smart Spin) than programmed. Check for an unbalanced load. |
AH |
Tilt Switch Error |
Maximum number of tilts was exceeded, skipping the final spin. Check load size and type. Check for an unbalanced load. |
Alrn or ALrn |
Break-in Alarm Error |
Access panel or coin vault switches. Power down machine to clear if Auto-Shutdown is on. |
Current Sensor Error |
Current Sensor Error |
When error occurs during a cycle, control records error. Cycle is aborted and Cycle aborted Error Menu is displayed until user clears error. |
DC Bus Error |
DC Bus Error |
When error occurs during a cycle, control records error. Cycle is aborted and Cycle aborted Error Menu is displayed until user clears error. |
door |
Door Open Indicator |
Door is not closed during an active cycle. If door is closed, check for improper wiring or inoperative door switches. |
Washer-Extractor (Ripon made) |
||
Display |
Description |
Cause/Corrective Action |
Door Lock Error |
Door Lock Error |
Control senses unlocked loading door during cycle and records error. Cycle is aborted and Cycle Aborted Error Menu is displayed. Clear error to return to Cycle Menu. |
Door Open Error |
Door Open Error |
Control senses open loading door during cycle and records error. Cycle is aborted and Cycle Aborted Error Menu is displayed. Clear error to return to Cycle Menu. |
Drain Alarm Error |
Drain Alarm Error |
When drain alarm time is exceeded, control records error. Cycle is stopped and Stopped Error Menu is displayed. Continue or abort cycle. |
Drive Balance Switch Error |
Control detects variable frequency drive (VFD) balance switch input is closed at start of drain steep and records error. Cycle is aborted an d Cycle Aborted Error Menu is displayed. Clear error to return to Cycle Menu. |
|
Drive Fault Error |
Control detects VFD fault switch is open and records error. |
|
E |
General Error |
Check keypad. |
E db |
Drive Balance Switch Error |
VFD balance switch closed at start of drain step. Power down machine. |
E dF |
Drive Failure |
Motor unplugged, motor failure, tachometer circuit open or drum locked up. Unpower machine to reset. |
E dl or E dL |
Door Lock Error |
Door does not lock immediately upon closing (open and reclose door) or doesn’t unlock 5 seconds after cycle completion. Power down machine and retry. |
E do, E:dO or E:do |
Door Open Error |
Control detects door open. Caused by pulling on door while locked or about to lock. Correct inoperative door locking system. End cycle. Power down machine to clear. |
E dr or E:dr |
Drain Alarm Error |
Machine did not drain, maximum drain time exceeded or water sensed at end of spin. Power down machine. |
E FL |
Programmed water level not reached within 5-90 minutes in any fill agitate cycle. End cycle. Power down machine to clear. |
|
E FS |
Frame balance switch is open. End cycle. |
|
E Ht |
Heat Alarm Error |
Programmed heat alarm time of 120 minutes or other programmed length of time is exceeded. Turns off heater output for remainder of cycle. |
Washer-Extractor (Ripon made) |
||
Display |
Description |
Cause/Corrective Action |
E Ld or E LF |
Water Leak Detection Error |
Control senses a drop or increase in water level during diagnostic testing. Power down machine to clear. Control shows error after door is open (when cycle is completed) for one minute or after test has been completed, the right-most decimal point on display lights and the error information will be logged in audit data. |
E oP |
Open Temperature Sensor Error |
Control senses temperature less than 0ºF (-18ºC). Heater and thermistor operations are disabled for cycle. |
E Pr |
Low Level Pressure Switch Error |
If control senses that low level pressure switch is in incorrect position at any point after first fill step in production test cycle. Cycle will terminate. Power down machine to clear. |
E ro |
Rotation Sensor Error |
Invalid signal from rotation sensor. Control will activate coast times to complete cycle. |
E rr |
Coin Error |
Invalid coin pulse or inoperative coin sensor. Check coin drop area and remove obstructions. If error persists, tampering may have occurred. Evaluate security procedures. |
E Sd |
Slow Drain Error |
Control senses the time required to drain the water is too long, the control shows error after door is open (when cycle is completed) for one minute, the right-most decimal point on display lights and the error information will be logged in audit data. |
E SH |
Shorted Temperature Sensor Error |
Control sense temperature greater than 220ºF (104ºC). Heater and thermistor operations are disabled for cycle. |
E SP |
Front End control cannot communicate with output board. Power down the machine, power up and try again. |
|
E Ub or E:Ub |
Unbalance Error |
Unable to balance load. Redistribute load and retry. |
E:dL |
Door Lock Error |
Door does not lock within 15 seconds of closing it or 3 minutes after cycle completion. Open and reclose door. |
E:FL |
Fill Error |
Pressure switch fails to open in 30 minutes in any fill/agitate cycle or maximum fill time exceeded. |
E:HT or E:Ht |
Takes more than two hours to reach programmed heat temperature. Replace inoperative heater circuit components. |
|
E:OP |
Open Temperature Sensor Error |
Open temperature sensor circuit wiring. Change sensor. |
E:Pr |
Pressure Switch Sequence Error |
Pressure switches out of sequence. Change pressure switch. |
E:SH |
Shorted Temperature Sensor Error |
Short in temperature sensor circuit wiring. Change sensor. |
Washer-Extractor (Ripon made) |
||
Display |
Description |
Cause/Corrective Action |
E:SP |
Serial Communication Error |
Master control cannot communicate with motor control. Master control will try to reset the motor control by powering it down. The error will display after three reset attempt failures. Caused by transformer unplugged or wiring to motor control incorrect. |
E3 |
Faulty Value or Damaged E Prom |
Re-program faulty value or replace the E Prom. |
E3 1 - E3 9 |
Probable Vend Price Error |
This indicates an incorrect price adjustment for the program (i.e., a coin value of "0" or larger than "1000" was programmed). Correct coin value adjustment. |
E4 |
Water Level Error |
The cycle's programmed water level was not reached within 15 minutes. Inspect the water inlet supply, water inlet valves, drain valve and water level switch. |
E5 |
Heating Error |
The cycle's programmed temperature was not reached within 80 minutes. Inspect the auxiliary heating system, temperature sensor and water safety switch. |
E5 |
Water Level Error |
The programmed water level was not reached after 80 minutes. Check inlet water supply, inspect inlet water valves, inspect drain valve and check water level switch. |
E6 |
Door Lock Error |
The door lock was released during the cycle. Inspect the door lock and door lock circuit. |
E7 |
Drain Error |
The water did not drain and the machine did not go into spin. Inspect the drain valve and drain outlet. |
E8 |
Temperature Sensor Error |
The temperature sensor's wiring or the temperature sensor is damaged. Inspect the temperature sensor's wiring. Replace the temperature sensor as needed. |
E9 |
Motor Protection Error |
The thermo-magnetic protection was activated 5 times, indicating a high motor current. Inspect the motor wiring connections, motor, contactors, input voltage, inverter, motor/ machine bearings and for excessive soap left in the basket at the end of the cycle. |
EA |
Tilt Switch Error |
The tilt switch was activated 15 times and the final spin was skipped, indicating an unbalanced load. Inspect the load size/type and the machine's drain valve. |
Eb |
Tilt Switch Error |
The tilt switch is activated at the start of a cycle or permanently interrupted. Adjust the tilt switch as needed and check load size and type. Inspect drain valves. |
EC:00 |
General Communication Error |
Communication failure. Try card again. |
EC:02 or EC02 |
Timeout Error |
Communication failure. Try card again. |
Washer-Extractor (Ripon made) |
||
Display |
Description |
Cause/Corrective Action |
EC:03 or EC03 |
Invalid Command Code |
Communication successful, but the command was not valid for this machine type, or the control could not perform the command in its current mode of operation. Before downloading, ensure data is for current machine type and control is in correct mode. |
EC:05 or EC05 |
Invalid or Out-of-Range Data |
Incorrect machine type or the value in at least one of the programming options is invalid or out of range. Before downloading, ensure data is for current machine type and recheck the programming option's value and try again. |
EC:06 |
Invalid Data Code |
Incorrect machine type. Before downloading, ensure data is for current machine type. |
EC:09 |
Corrupted Data Error |
Communication error. Try card again. |
EC:0A |
Invalid Machine Type |
Incorrect machine type. Before downloading, ensure data is for current machine type. |
EC:19 or EC19 |
No Card Reader Communication |
Communication failure. Check card reader, control and harness. Power down, power up and try again. If error persists, control or reader is inoperative. |
EC:20 |
Unreadable Card |
Inoperative card/ dirty contact. Clean chip on card or card reader contacts. Try card again. If error persists, card may be inoperative. |
EC:21 |
Security ID Mismatch |
Wrong card. Use card with correct security code. |
EC:22 |
Site Code Mismatch |
Wrong card. Use card with correct site code. |
EC:23 |
Card Maximum Value Exceeded |
Value on card over max. Use a card which does not exceed maximum value. |
EC:24 |
Insufficient Memory on Card |
Card memory is full. Download card contents to PC and clear card for re-use. |
EC:25 |
Card Reader Malfunction |
Inoperative Card Reader. Card Reader may need to be replaced. |
EC:26 |
Card Write Error |
Try card again. If error persists, card may be inoperative. |
EC:27 |
Diagnostic Test Card Write Failure |
Inoperative Card Reader. Card Reader may need to be replaced. |
EC:28 |
Diagnostic Test Card Read Failure |
Inoperative Card Reader. Card Reader may need to be replaced. |
EC:29 |
Diagnostic Test Memory Test Failure |
Inoperative Card Reader. Card Reader may need to be replaced. |
EC:2A |
Diagnostic Test Card Interface Failure |
Inoperative Card Reader. Card Reader may need to be replaced. |
EC:2b |
Diagnostic Test Flash Checksum Failure |
Inoperative Card Reader. Card Reader may need to be replaced. |
Washer-Extractor (Ripon made) |
||
Display |
Description |
Cause/Corrective Action |
EC:30 |
Timeout Error |
Card Reader may need to be replaced |
EC:31 |
Hotlisted Card Inserted Into Reader |
Card hotlisted. Control will destroy card. |
EC:50 |
Loyalty Purse Read Error |
Try card again. If error persists, card may be inoperative. |
EC:56 |
Loyalty Purse Write Error |
Try card again. If error persists, card may be inoperative. |
EC11 |
No Card Reader Initialization |
Communication is valid, but there is no card reader initialization. Power down, power up and try again. |
EC18 |
No Communication |
Card reader initialized, communication lost. Power down, power up and try again. If error persists, replace control or card reader. |
EC36 |
Audit Card Removed Prematurely |
Re-insert audit card and wait until machine prompts for card removal. |
Ed01 |
SPI Communication Error |
Front End control cannot communicate with motor drive. Power down, verify input power and 6-pin communication connection on drive and Front End control, power up and tray again. |
Ed02 |
DC Bus Error |
The control detects the DC bus is too high. Power down, verify line voltage is within specification, power up and try again. |
Ed03 |
Tachometer Error |
The drive detects the tachometer input is damaged during power up or no tachometer signal is detected after initiating motor output. Power down, verify H3 on drive and tachometer connections on motor, power up and try again. |
Ed04 |
Locked Rotor Error |
Motor does not reach speed at startup. Power down, verify motor mounting and look for obstructions, power up and tray again. |
Ed05 |
IGBT Overcurrent Error |
The drive detects an overcurrent shunt condition. Power down machine for a minimum of two minutes, verify the motor is not shorted phase to phase or phase to ground. Power up and tray again. If problem persists, replace drive. |
Ed06 |
Thermal Error |
The control detects a high IPM temperature. Power down, verify convection around drive heat sink, power up and try again. |
Ed07 |
No Setup Error |
The drive receives movement commands without receiving a setup packet. Power down, power up and try again. |
Ed08 |
Max Over Current Error |
The drive detects motor output overcurrent condition. Power down, power up and try again. |
Ed09 |
Current Sensor Error |
The drive detects a current sensor is not operating properly at startup. Power down, power up and try again. If problem persists, replace drive. |
Ed10 |
Low DC Bus Error |
The drive detects a low DC Bus voltage. Cycle will continue, no user input required. |
Washer-Extractor (Ripon made) |
||
Display |
Description |
Cause/Corrective Action |
Ed11 |
Invalid Command Error |
The drive received an invalid motor movement command. Cycle will continue, no user input required. |
EI:00 |
General Communications Errors |
Communication failure. Re-aim external device and try again. |
EI:01 or EI01 |
Transmission Failure |
Communication failure. Re-aim external device and try again. |
EI:02 or EI02 |
Device Timeout/Timeout Error |
Communication failure. Re-aim external device and try again. |
EI:03 or EI03 |
Invalid Command Code |
Communication successful, but the command was not valid for this machine type, or the control could not perform the command in its current mode of operation. Before downloading, ensure data is for current machine type and control is in correct mode. |
EI:04 or EI04 |
Expecting Upload Request or Command Packet Time Out |
Communication failure. Re-aim external device and try again. |
EI:05 or EI05 |
Invalid or Out-of-Range Data |
Incorrect machine type or the value in at least one of the programming options is invalid or out of range. Before downloading, ensure data is for current machine type, values entered are within the minimum and maximum limits and recheck the programming option's value and try again. |
EI:06 |
Invalid Data Code |
Incorrect machine type. Before downloading, ensure data is for current machine type. |
EI:07 |
Error Writing to RTC |
Control failure. Control may need to be replaced. |
EI:08 |
Error Writing to EPROM |
Control failure. Control may need to be replaced. |
EI:09 or EI09 |
CRC-16 Error |
Communication failure. Re-aim external device and try again. |
EI:0A |
Invalid Machine Type |
Incorrect machine type. Before downloading, ensure data is for current machine type. |
EI:0F or EI0F |
Invalid Wakeup or IR Disabled |
Communication failure or IR is disabled. Manually enable IR on control/Re-aim external device and try again. |
EI0A |
Framing Error |
Communication error. Re-aim external device and try again. |
EI0C |
Time-out Exceeded |
Communication error. Re-aim external device and try again. |
EI0E |
Encryption Error |
Incorrect machine type. Before downloading, ensure data is for current machine type and check security code and retry. |
EOP |
Temperature Sensor Error |
The temperature sensor has detected a temperature below 4 C. Check sensor wiring. Replace temperature sensor. |
Err |
Coin Error |
Invalid coin pulse or inoperative coin sensor. Check coin drop area and remove obstructions. If error persists, tampering may have occurred. Evaluate security procedures. |
Washer-Extractor (Ripon made) |
||
Display |
Description |
Cause/Corrective Action |
ERROR 1 |
Program Title Error |
After installation of new display board, the titles were not copied from mainboard to the display board. Copy titles to new display board. |
ERROR 2 |
Component Unknown |
A wash component is unknown in the wash program. Program new component. |
ERROR 3 |
Component Error |
Incorrect wash data - a wash component is created with incorrect length. Program correct wash data and correct length. |
ERROR 4 |
Subroutine Not Found |
Refers to unknown component. Program new component. |
ERROR 5 |
Wrong Password |
Incorrect password is used for entering test menu or editing menu. Enter correct password. |
ERROR 6 |
Wash Data Error |
Incorrect or incomplete wash data. Program correct or complete wash data. |
ERROR 7 |
Inverter Communication Error |
No communication or incomplete communication between inverter and mainboard. Inspect wiring between inverter and mainboard. |
ERROR 8 |
Inverter Autotuning Error |
Incorrect status during autotuning. Check status during auto tuning. |
ERROR 9 |
Inverter Parameter Error |
Writing of parameter is refused or error during writing of parameters to the inverter. Inspect wiring at inverter. Check parameter and reprogram. |
ERROR 10 |
Inverter Status Error |
Error message on the inverter. Check inverter. |
ERROR 11 |
Real Time Clock Error |
Read-out error on the clock. Inspect wiring at clock. Check clock and reprogram. |
ERROR 12 |
Tilt Switch Error |
Incorrect functioning or connection of the tilt switch when you start a cycle. Check tilt switch. Inspect wiring to the tilt switch. Using test program, check tilt switch’s input signal. |
ERROR 13 |
Temperature Error |
At startup, the temperature is higher than 95 C or after 6 minutes the temperature is still lower than 6 C or higher than 95 C. Inspect temperature sensor. Check water temperature. Check programmed temperature. |
ERROR 14 |
Temperature Error |
Inspect temperature sensor. Inspect heating resistances/relays and wiring. Check input/output voltage of temperature sensor on main board. Using test program, test temperature sensor. |
ERROR 15 |
Level Sensor Error |
At startup, the water level is lower than 4 cm, higher than 2 cm (positive offset) or higher than 10cm (negative offset). Check inlet water supply, inlet water valves, drain valve and water level switch. |
Washer-Extractor (Ripon made) |
||
Display |
Description |
Cause/Corrective Action |
ERROR 16 |
Can Communication Error |
No communication between the mainboard and the display board. Inspect the wiring between mainboard and display board. |
ERROR 17 |
Wrong Machine Type |
Incorrect machine type programmed with the wash data. Program correct machine type. |
ERROR 18 |
Wrong Wash Data Error |
Wash data on main board does not correspond with machine type. |
ERROR 19 |
ID Chip Read Error |
Error reading identification chip. Verify correct chip is in machine. Check wiring. |
ERROR 20 |
ID Chip Write Error |
Error by a writing action to the identification chip. Program correct action to the ID Chip. Check wiring. |
ERROR 21 |
MMC Transfer Error |
Error during the transfer of data to MMC Card. Check wiring. |
ERROR 22 |
Door Lock Error |
Door will not lock after 5 failed attempts in 10 seconds. Check door lock circuit. Inspect door lock mechanism. Using test program, check input signals S1 and S2. |
ERROR 23 |
Wash Data Version Error |
The wash data is not corresponding with the type of display. Reprogram was data. |
ERROR 24 |
Wrong Display Type Error |
Wrong display type programmed. Check display type. |
ERROR 25 |
Wash Data Backup Error |
Wash data will not backup. Check wiring. Check for sufficient space to save backup data. |
ERROR 26 |
New ID Chip Error |
Error when inserting new ID Chip. Verify correct chip is received for machine type. |
ERROR 27 |
Invalid File Size Error |
Incorrect file size. Check correct file size is programmed. |
ERROR 28 |
RTC Read Error |
Error when reading RTC. Verify correct RTC is in machine. Check wiring. |
ERROR 29 |
RTC Write Error |
Error by a writing action to the RTC. Program correct action to the RTC. Check wiring. |
ERROR 30 |
EProm Read Error |
Error when reading EProm. Verify correct EProm is in machine. Check wiring. |
ERROR 31 |
EProm Write Error |
Error by a writing action to the EProm. Program correct action to the EProm. Check wiring. |
ERROR 32 |
Water Level Too Low |
The water level was too low during the heating cycle. Check inlet water supply, inlet water valves, drain valve and water level switch. |
ERROR 33 |
Software Version Error |
When the main board or display board is replaced, the cards have different software versions. |
ERROR 34 |
MCU Failure Error |
The processor isn’t functioning properly |
Washer-Extractor (Ripon made) |
||
Display |
Description |
Cause/Corrective Action |
ERROR 50 |
Level Stop Error |
The programmed water level is not reached in a certain time. Check inlet water supply, inlet water valves, drain valve and water level switch. Using test program, test water inlet valves, water level sensor and drain valves. |
ERROR 51 |
Heat Stop Error |
The programmed temperature is not reached in a certain time. Check auxillary heating system, temperature sensor and water safety level switch. Using test program, test heating resistances and water level switch. |
ERROR 52 |
Drain Error |
Water level is not lowered within 2m after 2 minutes upon completion of a wash cycle (Machines with a drain valve, water level must be "0" after 8 minutes upon completion of a wash cycle and machines with a pump drain, water level must be "0" after 4 minutes). Inspect drain valve and drain outlet.Using test program, test function of drain valve. |
ERROR 53 |
Heating Error |
The programmed temperature is not reached after 20 minutes. Check auxillary heating system, drain valve and water level switch. Using test program, test heating resistances and water level switch. |
ERROR 54 |
Fill Error |
The programmed water level is not reached after 6 minutes. Check inlet water supply, inlet water valves, drain valve and water level switch. Using test program, test water inlet valves, water level sensor and drain valve |
ERROR 55 |
Rotation Sensor Error |
The rotation signal is missing for 30 seconds. Check rotation sensor. |
ERROR 56 |
Spin Retry Error |
Programmed number of imbalances is reached. Check load size and type. Check for an unbalanced load. |
ERROR 57 |
Extraction Error |
Error occurred during extraction. Check load size and type. Check for an unbalanced load. |
ERROR 58 |
Dry Error |
|
ERROR 59 |
Door Open While Washing Error |
The door is opened or unlocked during the operation of the machine. Check door lock circuit. Inspect door lock mechanism. Using test program, test function of door lock. |
ESH |
Temperature Sensor Error |
The temperature sensor has detected a temperature above 100 C. Check sensor wiring. Replace temperature sensor. |
F1 |
Control Error |
There is an invalid control configuration, wrong configuration file or corrupted PS40 firmware. Load a new configuration file. Replace PS40 E Prom. |
F5 |
Door Error |
The door open switch was tripped during the wash cycle. Check door lock circuit and inspect door lock mechanism. |
Washer-Extractor (Ripon made) |
||
Display |
Description |
Cause/Corrective Action |
F6 |
Door Error |
The door lock switch was tripped during the wash cycle. Check door lock circuit and inspect door lock mechanism. |
FA |
Out of Balance Error |
Out of balance switch was activated at start of cycle. Check load size and type. Check for an unbalanced load. |
FH |
Hardware Error |
There is a hardware problem or fault on printed circuit board. Replace print board. |
Fill Alarm Error |
Fill Alarm Error |
When fill alarm time is exceeded, control records error. Cycle is stopped and Stopped Error Menu is displayed. Continue or stop cycle. |
Frame Balance Switch Error |
Frame Balance Switch Error |
Control detects frame balance switch error during cycle and records error. Cycle is aborted. Power down machine and service frame balance switch error condition. |
Heat Alarm Error |
Heat Alarm Error |
When heat alarm time is exceeded control records error. Cycle is stopped and Stopped Error Menu is displayed. Clear error to return to Cycle Menu. |
Invalid Command Error |
Invalid Command Error |
When error occurs during a cycle, control aborts motor movement, control records error. |
Invalid Parameter Set Error |
Invalid Parameter Set Error |
Front End control cannot verify drive parameter set during a cycle, control records error. Cycle is aborted and Cycle Aborted Error Menu is displayed until user cleans error. If error occurs in any other mode, cycle power to clear error. |
IPM Over Temperature Error |
IPM Over Temperature Error |
When error occurs during a cycle, control records error. Cycle is aborted and Cycle aborted Error Menu is displayed until user clears error. |
IR |
When error occurs during IR communication, control records error. Display shows Communication Error Menu for 3 seconds. |
|
Last Drive Error |
Last Drive Error |
When error occurs during a cycle, control records error. |
LeU |
Drain Error |
Water is still in the tub at the end of a cycle. |
Locked Rotor Error |
Locked Rotor Error |
When error occurs during a cycle, control records error. Cycle is aborted and Cycle aborted Error Menu is displayed until user clears error. |
Low DC Bus Error |
Low DC Bus Error |
When error occurs during a cycle, control aborts motor movement, control records error. |
Washer-Extractor (Ripon made) |
||
Display |
Description |
Cause/Corrective Action |
Max Current Exceeded Error |
Max Current Exceeded Error |
When error occurs during a cycle, control records error. Cycle is aborted and Cycle aborted Error Menu is displayed until user clears error. |
MOT |
Motor Current Error |
No current supplied to the motor. Verify flat cable is connected. Check that the cycle contact MICRO 9 closes. Replace 16 amp fuse. Tighten motor plug. Replace motor print board. |
Mot 2 |
Rotation Sensor Error |
The rotation sensor's wiring or the rotation sensor is damaged. Inspect the rotation sensor's wiring. Replace the rotation sensor as needed. |
Mot 3 |
Operating Hours Error |
The machine has operated for 5,000 hours. Replace the motor brush blocks. |
Network Communications Error |
When error occurs during network communications, control records error. |
|
No Tachometer Error |
No Tachometer Error |
When error occurs during a cycle, control records error. Cycle is aborted and Cycle Aborted Error Menu is displayed. |
Not |
Motor Overload Protector Error |
Motor overload protector has tripped. |
not 1 |
Motor Current Error |
No current supplied to the motor. Verify flat cable is connected. Check that the cycle contact MICRO 9 closes. Replace 16 amp fuse. Tighten motor plug. Replace motor print board. |
Not 2 |
Speed Sensor Output Error |
The speed sensor's output does not match programmed speeds (variable-speed models only). |
not 2 |
Tach Pulse Error |
Motor print board is not receiving tach pulse from MICRO 9 control. Check wiring, replace tach generator and check contacts A, B, C or D of MICRO 9 control. |
not 3 |
Operating Hours Error |
The machine has operated for 5,000 hours. Replace the motor brush blocks. |
OFF or oFF |
Break-in Alarm Shutdown Error |
Access panel or coin vault switches. Opened with Break-In Alarm enabled. |
Open Temperature Sensor Error |
Open Temperature Sensor Error |
In machines equipped with temperature sensor, control senses temperature less than 5°F and records error. Cycle is aborted and Cycle Aborted Error Menu is displayed. Clear error to return to Cycle Menu. |
PDA Communicati ons Error |
PDA Communications Error |
When error occurs during communication, control records error. Display shows Communication Error Menu for 3 seconds. |
Washer-Extractor (Ripon made) |
||
Display |
Description |
Cause/Corrective Action |
Right most DP (decimal point) Lit |
Network Communication Error |
Communication failure. Wait for 1.5 minutes for error to clear. If it doesn’t, power-down and power-up the machine. If error persists, control or Network Board may need to be replaced. |
Right most DP (decimal point) Lit |
Check for water leak. |
|
rot |
Cylinder Error |
The cylinder is not turning. Check drive belt. Check rotation sensor. |
Rotation Sensor Error |
Rotation Sensor Error |
Control senses invalid signal from rotation sensor and records error. Cycle will continue with coast times loaded where rotation detection is required. Machine will operate this way until power is reset. |
Shorted IGBT Error |
Shorted IGBT Error |
When error occurs during a cycle, control records error. Cycle is aborted and Cycle aborted Error Menu is displayed until user clears error. |
Shorted Temperature Sensor Error |
Shorted Temperature Sensor Error |
In machine equipped with temperature sensor, control senses temperature less than 220°F and records error. Cycle is aborted and Cycle Aborted Error Menu is displayed. Clear error to return to Cycle Menu. |
SLE |
Drain Error |
Water is still in the tub at the end of a cycle. |
Slow Drain Detected During a Machine Cycle Error |
Slow Drain Detected During a Machine Cycle Error |
If slow drain error occurs during cycle, control records error and displays “Slow Drain Detected”. |
SPI Error |
SPI Error |
Control is unable to communicate with output board. Cycle is aborted and Cycle Aborted Error Menu is displayed. Clear error to return to Cycle Menu. |
Unbalance Error |
When machine detects unbalanced load during cycle, control will run subsequent Spray Rinse Extract and Extract steps but only at reduced speed. Cycle will continue. When cycle is completed, control records error. |
|
VEn |
Exhaust Error |
The exhaust air is restricted. Clean lint screen and inspect exhaust venting. |
Washer-Extractor (Ripon made) |
||
Display |
Description |
Cause/Corrective Action |
Water Leak Detection Error |
Water Leak Detection Error |
If control detects water leak or related problem during cycle, control will record error and display “Water Leak Detected”:Drain Valve or :Fill Valve at end of cycle. If control detects water leak or related problem during diagnostic test, control will record error and display “FAIL”:Drain Valve or :FillValve. If control detects water leak or related problemd uring auto-water leak detection, control will records error and display “FAIL”:Drain Valve or :Fill Valve until any keypad is pressed to return to Cycle Menu. |
Water Level Sensor Error |
Water Level Sensor |
Control senses high water level from water level sensor during extract cycle step and records error. Cycle is aborted and Cycle Aborted Error Menu is displayed. Clear error to return to Cycle Menu. |