Ironer |
||
Display |
Description |
Cause/Corrective Action |
001 |
Temperature of ironing roller is higher than 200°C (392°F) |
Wait until machine cools down or cool it down by ironing wet linen. Check the connection of the temperature sensor. If faulty, replace temperature sensor. |
002 |
Temperature of ironing roller is higher than 80°C (176°F) and roller does not rotate |
If roller stops due to any cause (pressing button for reverse operation, pushing crank for manual rotation, pressing the safety bar, drive failure), after 5 seconds the alarm sounds to warn of burning ironing belts. Switch machine off and on again. if the machine will not start, cool it down by wet linen and rotating handle. After cooling machine down below 80°C (176°C), repair the drive. |
003 |
Overloading of motor(s) of ventilator(s) |
Check and clean exhaust pipeline. If motors still overloading, check ventilators. |
004 |
Short circuit of temperature sensor |
Cool machine and replace sensor. |
005 |
Disconnection of temperature sensor |
Cool machine and replace sensor. |
006 |
Failure of drive |
Switch machine off and on again or let inverter cool down. If it doesn’t help, look for error according to individual instruction for inverter. |
007 |
Under pressure switches are off (gas heating only) |
One or two under pressure sensors detect correct function of combustion gases exhaust. if combustion gases exhaust is weak and there is danger of spreading combustion gases to the space around ironer, under pressure switches will open and by this the gas valve gets closed and the burner will turn off. Check and clean whole route of combustion gases exhaust. Check motor of ventilator and electrical installation. |
008 |
Failure of burner ignition (gas heating only) |
If flame ignition is not successful, the system will bring cause this error. Open the valve installed on the gas pipeline to ironer. Check the gas valve and make sure it is working properly. Remove sieve of mixer and check whether the jet is not clogged and whether the sleeve above jet is in correct height. Check whether ignition electrode is covered with flame when burner is burning. Check whether ignition electrode glows. |
009 |
Crank for manual rotation of ironing cylinder is pushed |
Release crank and start machine with start button or start revers operation. Check the microswitch on the crank. |
010 |
Lifting up the trough (only machines with ironer with front/ rear delivery) |
Close the trough and check the microswitch. |
Ironer |
||
Display |
Description |
Cause/Corrective Action |
011 |
Failure of under pressure switches |
Make sure under pressure switches are wired correctly. Be sure the switch is functioning. Replace if faulty. |
012 |
Wrong function of safety bar |
In case of jammed bar or switch, release it. Check the switch for correct operation. Make sure the switch connection is not faulty. Make sure the correct version of software and programming is being used. |
013 |
Defective speed sensor (IF machines only) |
Make sure sensor is not damaged. Adjust distance between sensor and rotating screen with teeth so that the light indicator on sensor is blinking when screen rotates. If indicator is constantly on, increase the distance. If it is constantly off, reduce the distance. If adjustment of diameter does not help, it is necessary to change the sensor. |
1 |
Safety thermostat error (temperature exceeds 210°C [410°F]) |
Replace thermostat. |
2 |
Exceeding the cylinder temperature over 200°C (392°F) |
The error will be accompanied by a symbol to indicated which sensor is causing the error. Replace sensor. |
3 |
Exceeding the cylinder temperature over 80°C (176°F) when machine is stopped |
The error will be accompanied by a symbol to indicated which sensor is causing the error. Replace sensor. |
4 |
Fan motors overloaded |
Indicates the fan motor is overheating/overloaded. Error can be canceled by the STOP key after the fan motor has cooled down. |
5 |
Temperature sensor short- circuited |
The error will be accompanied by a symbol to indicated which sensor is causing the error. Check wiring to sensor and replace sensor as needed. |
6 |
Temperature sensor disconnected |
The error will be accompanied by a symbol to indicated which sensor is causing the error. Check wiring to sensor and replace sensor as needed. |
7 |
Drive (frequency inverter) error |
This error indicates when a frequency inverter fault is detected or a fault of function or configuration parameter related to the frequency inverter. Refer to Programming Manual for list of error codes related to this drive error. |
8 |
Faulty function of under pressure sensors/value of the exhaust system resistance exceeds the limit value |
This error is displayed when an incorrect function of the airflow sensors and switches is detected. Refer to Programming Manual for list of error codes that indicate airflow sensor and switch failures. |
9 |
Error of the burner ignition unit (gas heating only) or fault of the electric heating contactors (electric heating only) |
For gas heating only, cancel the error by pressing STOP key and the automatic sequence of ignition unit reset is started and new ignition is initiated. Refer to Programming Manual for list of electric heating contactor errors. |
Ironer |
||
Display |
Description |
Cause/Corrective Action |
10 |
Faulty function of the finger protection safety bar at the machine start up |
Repair finger protection safety bar. Turn machine off and on again after repair has been made. |
11 |
Faulty function of the speed sensor |
Check wiring and replace sensor as needed. |
12 |
Number of steam heating cycles is reaching the limit value or the value has already been exceeded |
When this error occurs, a technical inspection of the machine must be made. After the inspection, the number of cycles should be reset to zero. |
13 |
Memory error |
A range of codes from 500-533 will be shown. If 504 is indicated, load default program by the LStPrg command from the configuration menu. If a different code is shown, reset default values using ResDef command from configuration menu. If error appears repeatedly, contact the manufacturer. |
14 |
Flash memory error |
A range of codes from 550-553 will be shown. Reset default values using ResDef command from configuration menu. If error appears repeatedly, contact the manufacturer. |
15 |
Software error |
A range of codes from 600-636 will be shown. If this error appears, contact the manufacturer. |
20 |
Motors of the vacuum table fans overloaded |
Indicates the insert table fan motor is overheating/overloaded. Cancel the error by pressing the STOP button and allow motor to cool. |
21 |
Automatic feeder error |
Indicates feeder motor is overheating/overloaded. Cancel the error by pressing the STOP button and allow motor to cool. |
22 |
Crosswise folding device or stacking device error |
Refer to Programming Manual for list of error codes and how they effect the machine. |
35 |
Incorrect software version |
This error occurs after a machine software update or when the machine is started for the first time or also after the control board has been replaced. Press STOP button and the screen for entering the configuration menus password is automatically displayed. Reset the default values by the ResDef command. |